The Kyoritsu 4102A-H Earth Tester - Hard Case Model price in bd is gifted with testing earth resistance occurring to 1200. This can be achieved via the 2-pole or 3-pole method once the supplied garnishing. The Kyoritsu 4102A Earth Tester is intended so that the atmosphere unwell of the earth voltage and earth resistance of the connect in crime spikes are neglected below the earth resistance test. A low measuring current of 2mA allows earth resistance tests to be performed without tripping earth leakage current breakers. The Kyoritsu 4102A Earth Tester Plus has the realization to operate earth voltage, occurring to 30V AC.
Small and lightweight, the Kyoritsu 4102A Earth Tester is both dust and Drip proof, conforming to the IP54 sociable plenty. The instrument is moreover admiration resistant and intended to meet IEC 61010-1 safety to your liking. The Kyoritsu 4102A-H Earth Tester is supplied once the earth resistance test leads, measurement scrutinized, collaborator spike kit, batteries, a shoulder strap, and a hard carry stroke.
If you are looking for this Earth tester the Kyoritsu 4102A is the best for you. Now you can get this at the best price in Bangladesh.
Key Features:
• In addition to the facility for precision measurement, test leads for a simplified two-wire measuring system are also supplied as standard accessories.
(The unit can be hung from the neck for simplified measurement)
• The latest circuit design permits the instrument to operate with the minimum influence from earth voltage and earth resistance of auxiliary earth spikes.
• Dust and drip proof. (designed to IEC 60529 IP54)
• Earth resistance value can be read directly from the scale.
• Designed to meet IEC 61010-1 safety standards.
• Capable of measuring earth voltage.
• Small and lightweight. Shock-resistant new case material.
• 2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test.
• Lead wire connection to C and P terminals and proper auxiliary earth resistance can be checked by the “OK” lamp. Lead wire connection to C and E terminals is good when the “OK” lamp is illuminated.
Earth resistance measurement |
x1Ω |
x10Ω |
x100Ω |
|
Measuring range |
0 - 12 Ω |
0 - 120 Ω |
0 - 1200 Ω |
Accuracy |
±3% of full scale |
Earth voltage measurement |
|
Measuring range |
0 - 30V AC (50/60Hz) |
Accuracy |
±3% of full scale |
Overload protection |
Earth Resistance: 276V AC/DC (10 seconds) Earth Voltage: 276V AC/DC (10 seconds) |
Applicable Standards |
IEC 61010-1 CAT III 300V Pollution Degree 2, IEC 61010-2-030, IEC 61557-1, -5, IEC 60529 (IP54) |
Power source |
R6 (AA) (1.5V) × 6 |
Dimensions |
105(L) × 158(W) × 70(D)mm (including case lid) |
Weight |
Approx. 600g (including batteries and case lid) |
Accessories |
7095A (Earth resistance test leads [red-20m, yellow-10m, green-5m/1set]) 7127B (Simplified measurement probe) 8032 (Auxiliary earth spikes [2spikes/1set]) 9121 (Shoulder strap) 9164 (Carrying case [Hard]) R6 (AA) × 6, Instruction Manual |
Optional |
7245A (Precision measurement cord set) 8259 (Adapter for measurement terminal) 9084 (Soft case) |