The Kyoritsu 4200 Clamp Tester is intelligent for measuring earth resistance levels along the middle of 0.05 and 1500, without the use of adding occurring spikes in multi-earthing systems. Featuring large jaws that are designed for clamping directly onto a targeted examination application, the Kyoritsu 4200 can play a part in AC. True RMS leakage or phase currents can be measured from 0.1mA to 30.0A to offer indispensable recommendations roughly the earthing network.
With a built-in filter to be fresh, the Kyoritsu 4200 is alert to eliminate electrical noise to withhold accurate results. These results are as well as nimble enough to be stored directly approximately the instrument, when a built-in memory for 100 readings. Other supplementary features unique to this earth resistance clamp meter include a panic sham, data maintenance, and a backlit LCD screen. If you need a rugged and reliable earth clamp tester you can use this one. Get it now at a reasonable price in Bangladesh.
Key Features: Kyoritsu 4200 Earth Clamp Tester
• The earth resistance from 0.05 to 1500Ω can be measured without the auxiliary earth spikes. (The Multiple Earthing System.)
• True RMS Accurate true RMS readings of AC including distorted waveform from 1mA to 30.0A
• Noise Check Function
A function to detect current, which affects an earth resistance measurement and displays a "NOISE" mark on the LCD.
• Memory function Save and display up to 100 measurement data.
• Data hold function / Buzzer function / Backlight function
• Compliant with Safety Standards of IEC 61010-1: CAT IV 300V Pollution degree2
Note:
A single earthing can not be measured. (Only for Multiple Earthing System)
Earth resistance Auto range |
20.00/200.0/1500Ω ±1.5%±0.05Ω(0.00 - 20.99Ω)* ±2%±0.5Ω(16.0 - 99.9Ω) ±3%±2Ω(100.0 - 209.9Ω) ±5%±5Ω(160 - 399Ω) ±10%±10Ω(400 - 599Ω) |
AC current (50Hz/60Hz) Auto range |
Values are displayed, but accuracy isn't guaranteed(600 - 1580Ω) 100.0/1000mA/10.00/30.0A ±2%±0.7mA(0.0 - 104.9mA) ±2%(80mA - 31.5A) |
Operating indication |
Earth resistance function : Constant voltage injection Current detection (Frequency: Approx.2400Hz) Dual Integration AC function: Successive approximation |
Over-range indication |
"OL" is displayed when input exceeds the upper limit of a measuring range |
Response time |
Approx. 7 seconds (Earth resistance) Approx. 2 seconds (AC) |
Sample rate |
Approx. 1 times per second |
Current consumption |
Approx. 50mA (max.100mA) |
Measurement time |
Approx.12 hours (when R6 is used) Approx.24 hours (when LR6 is used) |
Auto power-off |
Turns the power off about 10 minutes after the last button operation. |
Conductor size |
Approx. Ø32mm |
Applicable standards |
IEC 61010-1 CAT Ⅳ 300V Pollution degree2 IEC 61010-2-032, IEC 61326 (EMC) |
Power source |
DC6V : R6(sizeAA manganese battery) x 4 or LR6 (sizeAA alkaline battery) x 4 |
Dimensions |
246(L)×120(W)×54(D)mm |
Weight |
Approx. 780g (including batteries) |
Included Accessories |
R6 x 4, Instruction manual 8304 (Resister for operation check) 9166 (Carrying case[Hard]) |